Avery Dennison
MED 6773A
Double-Coated Nonwoven
MED 6773A is a double-coated, white, polyester/EVA nonwoven with an acrylic adhesive. This product is soft and conformable to most body contours.
Typical Application
Typical applications include electromedical applications, fixation devices and wound care applications.
Features and Benefits
- Conformable
- Breathable
- Die-cuttable
- Moisture resistant
- EtO and Gamma sterilizable
Physical Properties (Not intended as a specification.)
|
Test Method**
|
Typical Values*
|
---|---|---|
Peel Adhesion on Polyethylene (PE)
|
TDS-01
|
2.4 lbf/in 10.5 N/25mm
|
Finat Tack
|
TDS-07
|
0.7 lbf/in 3.0 N/25 mm
|
Static Shear
|
TDS-12
|
151 minutes
|
Liner Release
|
TDS-06
|
1.9 oz/in 96 g/25 mm
|
MVTR
|
TDS-16
|
42 g/100in2 /24h 644 g/m2 /24h
|
Product Construction
|
Typical Values*
|
Description
|
---|---|---|
Unwind Adhesive Thickness
|
0.8 mils 20 µm
|
Acrylic adhesive designed for medical applications
|
Carrier Thickness
|
14.0 mils 350 µm
|
White polyester/EVA nonwoven
|
Liner Adhesive Thickness
|
2.4 mils 60 µm
|
Acrylic adhesive designed for medical applications
|
Release Liner Thickness
|
3.2 mils 80 µm
|
White super-calendered glassine
|
*Refer to product specifications for material acceptance limits. **Test method information available upon request.
STORAGE AND SHELF LIFE
Two years when stored at 23°C (73°F), 50% relative humidity, out of direct sunlight, in original packaging.